From science to the field. DeepSport, with the evidence.
Three peer-reviewed publications. Different samples and test protocols. See under which conditions camera-based measurement was examined, with the methods and findings.
Open to knowledge. Linked to its source.
Choose a study.
See the research behind the measurement.
In jump measurement,
two views of the same movement.
DeepSport and OptoJump measured the same jumps simultaneously. CMJ and Squat Jump results were compared for validity and repeatability.
Repeatability, in numbers.
- Participants
- 12 Elite male basketball players
- Test scope
- CMJSquat Jump
- Method
- Simultaneous measurement with OptoJump
- Key finding
- ICC > 0.90; CV 2.12–4.95%
Method and detailed findings
Validity was assessed with Bland–Altman analysis and OLP regression; reliability with ICC and the coefficient of variation. The participants’ mean age was 21.53 ± 1.14 years.
| Jump height · ICC | 0.92–0.96 |
|---|---|
| Anaerobic power · ICC | 0.91–0.94 |
| Coefficient of variation · CV | 2.12–4.95% |
| Difference from OptoJump | p > 0.05 |
| Bland–Altman analysis | No systematic bias reported |
The findings of this comparison are limited to 12 elite male basketball players, the CMJ / SJ protocols and the measurement conditions of the study.
Performance beyond
a single jump.
Athletes with chronic ankle instability were compared with a control group. CMJ, agility and multidirectional hopping tasks were assessed with DeepSport.
32 athletes.
Two comparison groups.
- Participants
- 32 16 CAI · 16 control
- Test scope
- CMJ5–10–5ADAMultidirectional hopping
- Method
- Cross-sectional study · sex-adjusted
- Key finding
- Group differences in 5–10–5 and hopping tasks
Method and detailed findings
Thirty-two athletes were assessed in two groups. Group comparisons were adjusted for sex. Agility and multidirectional hopping tasks were more discriminating than general vertical jump variables.
| Sample | 16 CAI + 16 control |
|---|---|
| 5–10–5 agility | Group difference · p = 0.001 |
| Multidirectional hopping tasks | Significant group differences |
| ADA | Not significant after adjustment |
| CMJ variables | Not significant after adjustment |
This study illustrates a use in research. ADA and CMJ results showed no significant group difference after adjustment for sex.
This page does not offer risk prediction, diagnosis, treatment or any guarantee of injury prevention based on the publication.
The findings were written by checking them against the publication’s PubMed abstract and its PMC full text.
Measurement outside the water.
Inside swimming research.
The relationship between lower-limb performance and the Y-Balance Test was examined in competitive swimmers. DeepSport was used for CMJ and reactive strength measurements.
68 competitive swimmers.
Performance and balance.
- 01 Freestyle
- 02 Backstroke
- 03 Butterfly
- 04 Breaststroke
- Participants
- 68 Competitive swimmers
- Test scope
- CMJRSIY-Balance Test
- Method
- Comparison by swimming stroke
- Key finding
- Lower-limb performance and dynamic balance
Method and detailed findings
The study examines the performance of 68 competitive swimmers by swimming stroke. Higher jump and reactive strength values are reported in the butterfly and breaststroke groups; Y-Balance Test results are reported to differ by stroke.
| Sample | 68 competitive swimmers |
|---|---|
| DeepSport measurements | CMJ and RSI |
| Balance assessment | Y-Balance Test |
| Strokes compared | Freestyle, backstroke, butterfly, breaststroke |
CMJ and RSI were measured with DeepSport; dynamic balance was assessed with the Y-Balance Test. Use in a study does not mean that all product tests have been validated.
The title, sample and measurement scope are based on the publication details supplied by DeepSport; author, year and DOI details are not given on this page.
* The sum of the samples of three separate studies with 12 basketball players, 32 athletes and 68 swimmers. It is not a single validation cohort. The measurement scope is presented separately for each publication.
Every measurement means something under its own conditions.
A validity and reliability comparison and the use of a tool for measurement within a study answer different questions. We present the publications with this distinction, and we assess together in a demo the tests you would run in your organisation.
Try it in your organisation